Test sieve shaker jayant test sieves and sieves shaker. Tyler rotap is the industry standard for consistent, repeatable particle size testing. Rotap sieve shaker is widely used in pharmaceutical, metallurgy, building materials, chemical, geology and other industries for sieve analysis or particle size analysis. Rotap sieve shaker sieving impact civil engineering. The ro tap sieve shaker provides a compact design and aggressive sieving action. The design intent was to replicate and mechanize the hand motions required.
It is powered by a 14 hp motor and provides a builtin 99 minute stepdown timer. If the material is not soluble in water, accurate sieve analysis can be. You may have heard about our quality products, our innovative approach or our awardwinning customer service. Bring the top of the rotap sieve cover flush with the top of the upper carrying plate. Three versions of this csa software are available which differ in the scale of functions. Sieve shaker as 200 tap retsch reproducible sieve analysis. Build additional sieves into a primary screen deck if the p80 is suspected to be greater than 300 mesh. The results of measurements are documented for quality assurance purposes and can be introduced within the csa software into statistics and reports due to the complex data processi. Tylers products, please contact the customer service center at 18003216188 or use the contact us link below. The sieve support plate adjusts quickly to hold the desired number of sieves. We offer the greatest variety of test sieves concerning all relevant standards and designs and also laboratory test sieve shakers and virtually indispensable accessories for a complete sieve analysis.
Its tapping motion supports the sieve analysis of certain products such as activated carbon, abrasives, metal powder, spices and diamonds, as specified in the. The average time it takes to run a sieve analysis on a rotap is 810 minutes. The maximum feed quantity of 15 kg for sieving material means that it can also be used in pilot plant production or in test series for larger quantities. Software for particle size analysis sieving method laval lab. Leading manufacturer of woven wire mesh materials w. Place prepared deck on the rotap or sieve shaker for a minimum of 15.
The number of comparisons between particles and sieve apertures is. Clean and inspect screen deck, high or low grade, for any holes or tears. Operates with a verticallymounted, totally enclosed, 187w 1 4 hp motor. It reproduces the circular and tapping motion of hand sieving but with an even mechanical action. Sieve software easysieve for reliable sieving results retsch. You will need to run a few test analysis first to determine. The rotap sieve shaker was designed to use a hammer to assist in the agitation of particles to help. There are a lot of different particle analysis machines and systems out there that all have unique. Tyler rotap e sieve shakers is a larger floorstanding unit with a separate digital control panel that can be remotely mounted for convenient operation.
The ro tap is the required test sieve shaker in many industrial specifications. This does not include the time of analyzing the results. Tap sieve shakers are specified in various standards for particle size analysis. Thompson and many more programs are available for instant and free download. In order to achieve a sieve cut by air jet sieving, only a single sieve is used rather than a stack of sieves, and the sieve itself is not put into motion.
Equipped with a 99minute digital clocktimer, accurate to 0. Tyler recommends the product users develop their own quality control program. Sieve capacity is seven fullheight, ten halfheight sieves with a pan. Ss30 8in rotap sieve shaker holds up to six fullheight 8in 203mm test sieves with full height pan or thirteen halfheight sieves with a halfheight pan. Place the rotap sieve cover, with the cork installed, on top. Tyler, are specified for certain astm standards and are very well known in the north american industry.
The haver csa software enables pcaided evaluation of standard sieve analyses. Rotap sieve shaker the lab is equipped with a rotap sieve shaker for stacked sieve analysis, with a large suite of sieve sizes. The rx29e electronic is designed for 8 sieves and replaces the eml200t, and the rx30e sieve shaker has been replaced by part number 550051 metric equivalents. Sieve shakers and sifters for every application, including. The rotap is the required test sieve shaker in many industrial specifications.
Sieve analysis correlates with occhio inner diameter size parameter. The rotap test sieve shakers uniform, mechanical action ensures dependable and comparable results. The sieve support clamp bar is then adjusted, by looseningtightening the two nuts with the supplied wrench. Recording and management of sieve tare weights, monitoring of the sieve shaker analysette 3 pro and laboratory balance, automatic computation of particle size distribution from the sieved fractions, in conformity with predetermined sop standard operating. The rotap sieve shaker series are a manual alternative to the imp sieve master 200 and 300 automated particle size analysis machines. Easysieve, the software for particle size analyses, exceeds manual evaluation in many aspects, due to the fact that the software is able to automatically control the necessary measurement and weighing. Ws tyler sieve sound enclosure for rotap test sieve. Csa software for digital evaluation of sieve analyses. Test sieve shaker accessories learn more to learn more about w. You will need to run a few test analysis first to determine the exact time for your material. Tyler rx30 rotap 12 inch sieve shaker 110 volts 60 hertz holds 4 full height sieves, 6 intermediate height sieves or 8 half height sieves.
The ro tap model b shaker is designed to allow analysts to obtain particle size distributions of various materials in a standardized way by delivering consistent vertical and horizontal force on a sieve stack. Tyler has been a leader in the design, engineering, and manufacturing of woven wire cloth and mesh materials. The average time it takes to run a sieve analysis on a ro tap is 810 minutes. The rotap sieve shaker, with its rotating movement and tapping energy, provides consistent, repeatable sieving analysis results. This 3d animation offers a close up look at the rotap and what it can do for your business. Easysieve, the software for particle size analyses, exceeds manual evaluation in many aspects, due to the fact that the software is able to automatically control the necessary measurement and weighing procedures from the registration of the weight of the sieve up to the evaluation of the data. Rotap sieve shakers solutions for sampling to analysis. The sieves, usually 6 plus the bottom pan, are placed on the movable plate with stack supports to keep the sieves together and on the plate. Today, the rotap test sieve shaker, with its rotating movement and tapping energy, provides for the most consistent, repeatable sieving analysis results. Place prepared deck on the rotap or sieve shaker for a minimum of 15 minutes.
It depends on your application which test sieves should be used for sieve analysis with the w. The vibratory sieve shaker analysette 18 is primarily used for particle size analysis and grading of coarsegrained materials. Sieves shaker jayant test sieves shakers manufacturer. Ws tyler offers sieving software for basic spreadsheet analysis. Screen the coarse sample through the primary screen deck first on the ro tap. The horizontal, circular motion with vertical tapping action assures accurate. Gilson performer iii sieve shaker the lab has two gilson performer iii sieve. Particle size and grain size analysis, sieve analysis method according to astm e11 and iso 3310 standards, rotapa. Recording and management of sieve tare weights, monitoring of the sieve. Add minus product from step 5 to the standard decks and proceed as in step 2. We invite you to learn more about our wide selection of highperforming products. Recommended for testing applications requiring analysis of particles from 5 in. Add the dried and cooled plus product to the top screen in the deck. Tyler rotap rx94 for test sieves up to 203 mm diameter can take 2 sieve sets simultaneously.
Place prepared deck on the ro tap or sieve shaker for a minimum of 15 minutes. Tyler rotap sieve shakers generate 278 oscillations and 150 taps per minute as required by some astm methods. But youll likely remember us for our relentless passion for precise engineering. Ro tap sieve shaker the lab is equipped with a ro tap sieve shaker for stacked sieve analysis, with a large suite of sieve sizes. Tyler rotap particle analysis test sieve shakers by. Tylers product or to obtain specific information about w. Test sieves and test sieve shakers are prescribed for conventional sieve analysis of bulk material, whereby haver particle analysis sets benchmarks in quality and diversity. Services are offered to those involved with their own internal or iso 9000 series quality programs. Sieve shakers are often manufactured to accomodate certain sample types. Sieve shakers and sifters for every application, including sonic, vacuum,rotap,vibratory m200 electromagnetic. Gilson performer iii sieve shaker the lab has two gilson performer iii sieve shakers used for sample preparation psda as well as for stacked sieve analysis of smaller quantity samples.
Today, the ro tap test sieve shaker, with its rotating movement and tapping energy, provides for the most consistent, repeatable sieving analysis results. The ws tyler company is also the north american leader for analytical test sieves of all sizes. Tyler test sieve shakers were designed for functional use, providing reliable, accurate and consistent particle analysis service. They are typically used in a laboratory setting for. Unit operates at 1750 rpm and accommodates 8 diameter or 200 mm testing sieves with any mesh size. In addition to this, the rendered productline includes products like gyratory sieve shaker, ro top sieve shaker, table model analytical sieve shaker, rotap sieve shaker and table top sieve shaker. The rotap model b shaker is designed to allow analysts to obtain particle size distributions of various materials in a standardized way by delivering consistent vertical and horizontal force on a sieve stack.
Tylers products, please contact the customer service center at 1800321. They are typically used in a laboratory setting for applications which require a rotary shaking and tapping action. Some force may be required to move the support clamp bar on the rotap ii rx94. The rx29 holds 6 full height 8 inch diameter sieves screens. Used for soils, geological materials, alloys, and a host of other solid. Tyler rotap wet test kit for use with rotap ii sieve. Recommended for the separation of particle sizes ranging from no. Software for automatic particle size analysis autosieve. Tyler rotap sieve cover 560067 eshop particle analysis. It is suitable for up to 6 test sieves with full height or halfheight sieves and one sieve pan with a diameter of up to 203 mm 8 or 200 mm. Sieve shaker testing sieve shaker accurately reproduces circular and tapping motion of handsieving with uniform mechanical action to ensure dependable, comparable tests.
Shaker features vertically mounted 14hp motor and has a builtin 99minute digital timerclock accurate to 0. Aug 11, 2017 the same evaluation software easysieve can be used to control this sieve shaker. Astm d1921 sieve analysis rotap by ws tyler sound enclosure and stand sieves sieve analysis astm d1921 rotap shaker, sieves, and sound enclosures manufactured by w. We offer a wide selection of particle analysis equipment. Sieves of any special specification can be manufactured on request like conical sieves and wet sieves for wet analysis, we also manufacture sieve with wooden or stainless steel and aluminium frame. The rotap sieve shaker provides a compact design and aggressive sieving action. Standard method for sieve analysis of fine and coarse. Tyler rotap rx29 for test sieves up to 203 mm diameter reproduces the circular and tapping motion of hand sieving but with an even mechanical. This shaker provides 278 oscillations and 150 taps per minute to produce an effective sieving action. Because of the way a sieve shaker is designed, they can be quite noisy.
Tyler rotap rx has a unique two dimensional operation. Sieve shakers, sieve analysis, test sieves laval lab. Rotap sieve shakers are used for laboratory testing of particle size and size distribution in samples of solid materials. With our variety of test sieve shakers for dry and wet sieving all materials can be classified, also agglomerating grinding. Ws tyler sieve sound enclosure for rotap test sieve shaker. It is suitable for up to 6 test sieves with full height or halfheight sieves and one. The autosieve software for windows is designed for a professional evaluation of particle size analysis by the sieving method. Moderate tension of the mounting bolts is all that is required.